System tools 44
10.2. CONFIGURING OPERATION AND PROGRAMMING PARAMETERS
Below, the distinct parameters found in the CONFIGURATION menu are listed.
Shown at each parameter:
Identification of the parameter: description that appears on the screen
Explanation of the parameter
Configurable values or range
Configuration at works: the configuration at works of the washing machine will depend on the purchase
specifications
Configuration by default: is the option programmed by default at the washing machine control. The
values configured by default will always appear when a GENERAL INITIALIZATION is executed or when
a new control board is installed onto the washing machine.
When the configuration value at works and the default configuration value coincide, it is only indicated as
the value at works.
To provide better access the parameters are grouped in three submenus:
Operation parameters. Section 10.2.1.
Advance programming options. Section 10.2.2.
Modifiable values table. Section 10.2.3.
10.2.1. Operation parameters
LANGUAGE
Permits selecting the language of all the written messages.
Programmable values
...... ESP (Spanish) | ENG (English) | FRA (French)
Configuration at works ..... depending on specification
Value by default ............... Spanish
SCREEN CONTRAST
Permits modifying the contrast on the washing machine screen.
Programmable values
0 (less contrast) ... 9 (more contrast)
Configuration at works ..... 5
LOGO
Permits selecting the initial Logo and the screen saver.
Programmable logos
........
GIRB (GIRBAU) | CONT (CONTINENTAL) | OTHERS (MICROPROCESSOR
CONTROL)
Configuration at works ..... depending on specification
Value by default ............... GIRB (GIRBAU)
Atention.
Selecting OTHERS from the logo option, the English language and the temperature in Fahrenheit degrees
are automatically selected.
A GENERAL RESET at the SETUP menu doesn’t modify the OTHERS logo option.
TEMPERATURE UNIT
Permits selecting the unit that the temperature values are displayed .
Programmable values
......
C (centigrade) | F (Fahrenheit)
Configuration at works ..... depending on specification
Value by default ............... centigrade