Programming a new program 31
Washing machines with external dosing system
The Microprocessor Control allows activating four electric signals to control an external dosing system.
The connection board of these four signals is installed as standard in all the washing machines and located
at the rear side of the machine. Consult the location and characteristics of the connection in the
corresponding Installation Manual.
The external dosing signals programming is independent of product dosing programming through the washer
dispenser.
The number that appears in the icons corresponds with the number of the label attached next to the
connection terminals.
Dosing by external dosing system
Optional programming. As an option, the number of electric signals of external dosing control can
be increased to a maximum of twelve. To have the additional eight signals available, it is necessary to have
the optional A6 input and output board (I/O2) in the washing machine and to conveniently activate it in the
SETUP menu.
7.3.6. Duration of the dosing.
Optional programming
In default configurations, the time of each dosing is set at 40 seconds.
However, the Microprocessor Control allows programming the length of each dosing.
This function appears after product dosing has been programmed, only if the parameter has been activated
in CONFIGURATION.
Programmable time range: 1 – 231 seconds
Value programmed by default: 1 sec.
7.3.7. Rotation. Start – Stop Sequence
This function allows selecting distinct start-and-stop drum rotation sequences.
The programmed sequence is maintained during the entire phase.
There are five pre-programmed rotation sequences that are modifiable in the CONFIGURATION of the
washing machine.
Value ON: drum rotation time in seconds
Value OFF: drum stoppage time in seconds
Programmable reverse sequences Default values
No rotation
There is no drum movement
Reverse sequence 1 WR1
ON: 5sec. – OFF: 55sec.
Reverse sequence 2 WR2
ON: 5sec. – OFF: 10sec.
Reverse sequence 3 WR3
ON: 5sec. – OFF: 25sec.
Reverse sequence 4 WR4
ON: 15sec. – OFF: 15sec.
Reverse sequence 5
< < < Option programmed by default
WR5
ON: 25sec. – OFF: 5sec.