Chapter 5 Configure and Start Up the Kinetix 350 Drive System
Table 37 - Axis State Status Indicator
Table 38 - Network State Status Indicator
Status Indicator State
Off Off
Flash red/green Self test
Off Initialization - bus not up
Flashing green Initialization - bus up
Off Shutdown - bus not up
Flashing amber
(1)
(1) The axis and the drive define minor fault conditions. While a minor fault does not affect the drive status
indicator, it does affect the axis status indicator. When a minor fault condition is detected, a normally solid green
status indicator indication changes to alternating red-green-red-green, a normally flashing green status
indicator indication changes to alternating red-off-green-off, and a normally flashing amber indications
changes to red-off-amber-off.
Shutdown - bus up
Off Pre-charge - bus not up
Flashing amber
(1)
Start inhibit
Flashing green
(1)
(2)
(2) The drive also defines alarm conditions. When an alarm condition is detected, a normally solid green status
indicator indication changes to alternating amber-green-amber green while a normally flashing green status
indicator indication changes to alternating amber-off-green-off.
Stopped
Solid green
(1)
(2)
Stopping
Starting
Running
Tes ti ng
Flashing red
Aborting
Major faulted
Solid red
Aborting
Major faulted
Status Indicator State
Steady off Not powered, no IP address
Flashing green No connections
Steady green Connected
Flashing red Connection time-out
Steady red Duplicate IP
Flashing green and red Self-test