A SERVICE OF

logo

18 Rockwell Automation Publication 2097-UM002A-EN-P - December 2013
Chapter 2 Install the Kinetix 350 Drive System
Use 2090 series motor feedback cables or use connector kits and properly
terminate the feedback cable shield. Drive-to-motor power and feedback
cables must not exceed 20 m (65.6 ft).
Refer to the System Design for Control of Electrical Noise Reference Manual,
publication
GMC-RM001, to better understand the concept of electrical noise
reduction.
IMPORTANT
System performance was tested at these cable length specifications. These