American Dryer Corp. MLG-460 Clothes Dryer User Manual


 
88
TUMBLER (Basket) FORWARD “PENDANT” - PB1
This push button comprises of one normally open switch, and is mechanically interlocked with the
Tumbler (Basket) Reverse Push button.
EMERGENCY STOP ((E-Stop) “PENDANT” - PB6
This push button switch is normally open device and its function is to shut down the control voltage to
the dryer in the event it is pressed.
NOTE: It will not effect the sprinkler circuit power.
2. Verify Pendant Electrical Signals
ALL the pendant control signals are interfaced to the Main Electrical Panel’s PLC (Programmable Logic
Controller) except for EMERGENCY STOP (E-Stop).
Load - Level - Unload -A and B
Tumbler (Basket) Reverse Switch - PB2
Tumbler (Basket) Forward Switch -PB1
EMERGENCY STOP (E-Stop) Switch - PB6
For a quick check of the wiring of SEL 1 and 2 to the PLC (Programmable Logic Controller) perform the
following test with the control voltage “ON” (“GREEN” Button);
Turn the selector switch to “LOAD.”
Does PLC (Programmable Logic Controller) input L.E.D. (light emitting diode) #15 light?
Turn the selector switch to “UNLOAD.”
Does PLC (Programmable Logic Controller) input L.E.D. (light emitting diode) #16 light?
Turn the selector switch to “LEVEL.”
Are both PLC (Programmable Logic Controller) (input #15 and input #16) “OFF”?
If the answers to these question are “YES,” wiring to the PLC (Programmable Logic Controller) is
correct.
If any answer to these questions is “NO”, refer to Probable Causes paragraph on page 89.
Tumbler (Basket) Reverse Switch PB2
For a quick check of the wiring of PB2 to the PLC (Programmable Logic Controller) perform the following
test with control voltage “ON”. (“GREEN” Button)
Press the REVERSE push-button.
Does PLC (Programmable Logic Controller) input L.E.D. (light emitting diode) #18 light?