If the de-energizing time is incorrect:
Adjust the “time adjust” on the stop motion detector module and retest.
If the input #0, 10 on the PLC (Programmable Logic Controller) is not on after several rotations
of the tumbler (basket):
Check fuse #2 and replace if necessary.
Rotate the tumbler (basket) using the pendant control in ”LOAD POSITION.” Does the
module’s L.E.D. (light emitting diode) respond?
If yes, adjust the “sense time” until the L.E.D. (light emitting diode) stays on for 12 to 15
seconds after the tumbler (basket) stops, then refer to Section 7a on page 72.
If no, check:
Inductive proximity sensor for damage.
Sensor distance from targets is 3/16”. The proximity sensor is located in the same area as
the tumbler junction box.
Inductive proximity adjustment.
Tumbler (basket) target.
Stop motion detector module.
Circuit wiring;
Refer to the dryer’s Main Panel Wiring Diagram, dryer’s Tumbler Junction Box Wiring
Diagram.