American Dryer Corp. MLG-460 Clothes Dryer User Manual


 
37
D. GAS BURNER and IGNITION SYSTEM
The dryer’s gas burner system operates an on/off gas rate sequences to accurately control the tumbler’s (basket’s)
drying temperature. Maximum firing rate is 2,800,000 Btu/hr (705,600 kcal/hr).
Upon a call from heat, the dryer computer sends a 120 volt signal to the burner controller module (BCM) which
initiates and controls the ignition sequences. The burner controller module (BCM) insures that ALL the safety
switches are closed before turning on the combustion air burner fan, then checks to ensure that the burner fan
air switch has closed. The pilot gas flame is then established, the flame rod (which sits in this pilot flame) comes
in contact with the flame and signals the BCM. The main motorized gas valves open in sequence and full
operational flame is achieved.
The burner controller module (BCM) has five (5) L.E.D.’s (light emitting diodes) on its cover and two (2) neon’s
on the mounting base for ease of troubleshooting, as well as dip switches inside for ease of programming.
The burner controller module (BCM) controls ALL of the gas burner ignition components, except for the
motorized gas valve. When the drying set point temperature is reached, the dryer’s computer closes the top
motorized gas valve, shutting off full flame.