American Dryer Corp. MLG-460 Clothes Dryer User Manual


 
31
1) Front Panel Electrical Connections:
a) Front Position Switch Disconnect Plug;
The front door position switch disconnect plug is located on the left side of the front doors.
Disconnect this plug and feed the cable through the right hand side of the tumbler section.
b) Intake Temperature Probe Disconnect Plug;
The intake temperature probe disconnect plug is located in the burner and heater section, just
above the 25 HP motor. Disconnect this plug and route through the hole located on the right of the
front panel.
2) Rear Panel Electrical Connection Plug;
a) Rear Panel Controls Disconnect Plug;
The rear panel controls disconnect plug is located behind the rear panel controls. Disconnect this
plug and feed through hole towards the left hand drum motor section.
b) Rear Door Position Switch Disconnect Plug;
The rear door position switch disconnect plug is located on the left side of the rear doors. Disconnect
this plug and feed the cable through the right hand side of the tumbler section.
Put a block of wood under the tumbler; loosen and back out the tumbler shaft support bearings so
that the drive wheel lines up with the large hole in the frame. The drive wheel taper lock bushing
can now be loosened and removed through the hole in the frame, and the drive wheel pulled out of
the dryer through this hole. Before backing out the tumbler shaft bearings mark their position on
the frame to make reassembly easier.
5. Tumbler (Basket) Retaining Wheels
There are eight (8) 4-7/16 (11.27 cm)diameter retaining wheels which stabilize the tumbler’s (basket’s)
position from front to back. Four (4) of these are mounted on the front panel of the dryer (two [2] on the left
side and two [2]) on the right side), and four (4) are mounted on the rear panel (two [2]) on the left side and
two [2] on the right side). Access to these wheels is obtained by removing the vertical front and rear panel
covers.