77
b) POSSIBLE SOLUTIONS;
1b) If either the Drum forward or reverse functions (rear) does not respond:
Verify that the rear panel controls disconnect plug is indeed connected. This disconnect plug
allows for the removal of the rear control panel for dryer servicing.
2b) Defective Forward and Reverse Switch
Shut power off at the main breaker and remove the rear panel and check switches using an OHM
meter; replace if defective.
Retest
3b) Wiring Back to Main Electrical Enclosure
With the control voltage “ON” front panel “GREEN” button
Select “1” on the “O UNLOAD 1” switch located on the rear controls panel.
Have someone PRESS either the forward or reverse buttons while you watch the input L.E.D.s
(light emitting diode) of the programmable controller. Do the associated L.E.D.s light?
PLC PIN 20 = DRUM FWD., REAR PANEL
PLC PIN 21 = DRUM REV., REAR PANEL
If yes, refer to paragraph 2 (section a) on page 75.
If no, refer to paragraph 2 (section b) on page 76.
4b) The L.E.D.s (light emitting diodes) illuminating on the PLC (Programmable Logic Controller)
indicate that the wiring to the PLC is correct.
Check FUSE #2 on the Main Electrical Panel
Check wiring back to the Tumbler Junction Box
Check wiring back to the rear controls
Refer to wiring diagrams:
Main Electrical Panel Diagram
Tumbler Junction Box Wiring Diagram
Rear Panel Controls Wiring Diagram
Retest