American Dryer Corp. MLG-460 Clothes Dryer User Manual


 
84
If no, check associated:
Switch and Wiring
Check wiring back to the Base Electrical Junction Box
Check PLC (Programmable Logic Controller)
Refer to Wiring Diagrams:
Main Electrical Panel Diagram
Base Electrical Junction Box Wiring Diagram.
Retest; verify that the signal is operational.
3b) Place the dryer in the UNLOAD position; TILTED FORWARD
Actuate the Rear Down switch by hand.
Have someone verify that PLC (Programmable Logic Controller) input L.E.D. (light emitting
diode) #12 lights when the switch actuator is down, and is OFF when the actuator is up.
Does L.E.D. (light emitting diode) #12 come “ON” when the switch is down?
If yes, wiring is OK.
Check switch, actuator placement and tilt actuation.
NOTE: If actuator is at a 90° or greater angle with the base, the actuator will damage if machine is
lowered.
If no, check associated:
Switch and Wiring.
Check wiring back to the Base Electrical Junction Box.
Check PLC (Programmable Logic Controller).
Refer to Wiring Diagrams:
Main Electrical Panel Diagram
Base Electrical Junction Box Wiring Diagram.
Retest; verify that the signal is operational.