17
d. Pendent
On the top of the heat console section of the dryer near the pendent, there is a junction box with four (4)
cables coming out of it. Two (2) of the cables from the junction box have connectors on the end, a 5-pin
connector and an 11-pin connector. Coming out of the pendent should be two (2) cables, one with a 5-
pin connector and the other with an 11-pin connector. Match up the four (4) cables into assigned pairs,
check keying and connect the male and female connection together.
e. Tumbler Junction Box Disconnect
Remove the four (4) bolts that hold on the lower left side panel, then remove the panel. The safety panel
is next to be removed. This is done by removing the six (6) bolts on the bottom of the safety panel where
the tumbler (basket) section and the base meet. Reach into the feed through hole in the base of the
tumbler (basket) section, there will be two (2) cables there. Pull both cables through the hole into the
tumbler (basket) section. The cable with the connector on the end is for the tumbler (basket) junction
box, the other cable is for the left drum motor. Leave that cable in the tumbler (basket) section (it will be
covered in Section f [Left Drum Motor] on page 18). Check keying between the plug and tumbler
(basket) junction box. Insert plug into connector on the junction box and engage locking clasps. Leave
the lower left side panel and the safety panel off the machine until left drum motor is reconnected (refer
to Section f [Left Drum Motor] on page 18).