A SERVICE OF

logo

EQQZ187E EQQZ192E
EQQZ187E CHECKPOINT DATASET WAS NOT INITIALIZED
Explanation: During the startup with OPCOPTS OPCHOST(PLEX) was found that the checkpoint dataset is not
initialized. This is not supported.
System action: TME 10 OPC stop processing.
System programmer response: Start one TME 10 OPC controller with OPCOPTS OPCHOST(YES) to initialize the
checkpoint dataset with the correct FMID and service level for a Sysplex Controller configuration.
EQQZ188E UNEXPECTED RETURN CODE DURING SYMBOL SUBSTITUTION
Explanation: During symbol substitution an unexpected return code was issued by MVS symbol substitution
services. Diagnosis messages will be shown.
System action: TME 10 OPC stop processing.
System programmer response: Save the parameter dataset definitions, the message log and the current values of
MVS static symbols. Contact your IBM service representative. A possible circumvention is to remove the symbols
from the PARMLIB member being processed.
EQQZ189W OPCOPT OPCHOST(PLEX) WAS SPECIFIED BUT NO TAKEOVER KEYWORD FOR THE XCFOPTS
STATEMENT WAS FOUND
Explanation: The initialization statement OPCOPT OPCHOST(PLEX) was specified, but no TAKEOVER keyword for
the XCFOPTS statement was coded. This is necessary to avoid operator intervention in a takeover situation.
System action: TME 10 OPC startup continues.
System programmer response: Code either TAKEOVER SYSFAIL, or HOSTFAIL, if appropriate.
EQQZ190E THE FMID
FILEFMID OF DATASET FILENAME
DOES NOT MATCH OPC CODE FMID
OPCFMID
Explanation: The FMID
FILEVER
of the dataset
FILENAME
doesn't match the FMID
OPCVER
of the code trying to
access the file.
System action: Either the program or TME 10 OPC initialization is terminated.
TME 10 OPC administrator response: Contact your system programmer.
System programmer response: Check that the level of TME 10 OPC matches the level of the file indicated in the
message. Possible explanations include running on backlevel code or backlevel dataset. Correct the errors and
restart either TME 10 OPC or the program.
EQQZ191E THE CHECKPOINT DATA SET, DDNAME EQQCKPT, COULD NOT BE OPENED
Explanation: The EQQMAJOR could not open the checkpoint dataset, which is a required dataset for TME 10 OPC.
System action: TME 10 OPC initialization is terminated.
TME 10 OPC administrator response: Contact your system programmer.
System programmer response: Check that ddname EQQCKPT is correctly specified and the TME 10 OPC started
task is authorized to open the dataset for updating. Correct the errors and TME 10 OPC.
EQQZ192E THE VERSION
FILEVER OF DATASET FILENAME
DOESN'T MATCH OPC CODE VERSION
OPCVER
Explanation: The version FILEVER of the dataset FILENAME doesn't match the version OPCVER of the code trying
to access the file.
System action: Either the program or TME 10 OPC initialization is terminated.
TME 10 OPC administrator response: Contact your system programmer.
System programmer response: Check that the level of TME 10 OPC matches the level of the file indicated in the
message. Possible explanations include running on backlevel code or backlevel dataset. Correct the errors and
restart either TME 10 OPC or the program.
Chapter 33. EQQZnnn Messages 431