A SERVICE OF

logo

EQQR666E EQQR671E
EQQR666E AN ABEND HAS OCCURRED IN A SUBSTITUTION USER EXIT
Explanation: The user module caused an ABEND, from which TME 10 OPC recovered.
System action: The system waits for you to respond.
User response: Contact your system programmer.
System programmer response: Check the TME 10 OPC message log and look for message EQQJ515.
EQQR667E AN UNRECOVERABLE ABEND HAS OCCURRED IN A SUBSTITUTION USER EXIT
Explanation: The user module caused an ABEND, from which TME 10 OPC could not recover.
System action: The system waits for you to respond.
User response: Contact your system programmer.
System programmer response: Check the TME 10 OPC message log and look for message EQQJ516.
EQQR668E AN INVALID VALUE WAS RETURNED FROM A VARIABLE SUBSTITUTION EXIT
Explanation: The value that the user supplied for the variable violates the verification rules in the variable definition.
System action: The system waits for you to respond.
User response: Contact your system programmer.
System programmer response: Check the TME 10 OPC message log and look for message EQQJ517.
EQQR669E A COMP EXPRESSION THAT EXCEEDS 1024 BYTES IN LENGTH WAS ENCOUNTERED
Explanation: The total length of all fields of a COMP expression, including COMP= and all continuations of the right
side of the expression on subsequent JCL lines, cannot exceed 1024 characters after substitution.
System action: The system waits for you to respond.
User response: Contact your system programmer.
System programmer response: Check the TME 10 OPC message log and look for message EQQJ542.
EQQR670E A SUBSTITUTION USER EXIT SET ERROR RETURN CODE
Explanation: A substitution exit set return code 8, which interrupted the JCL variable substitution. No further
substitution is done for this operation.
System action: The system waits for you to respond.
User response: Contact your system programmer.
System programmer response: Check the substitution exit to determine the cause of this return code.
Check the TME 10 OPC message log and look for message EQQJ539.
EQQR671E OPC/ESA WAS UNABLE TO LOAD A USER EXIT
Explanation: TME 10 OPC could not load a substitution or JCL imbed exit.
System action: The system waits for you to respond.
User response: Contact your system programmer.
System programmer response: Check the current load library in the started task JCL, and make sure the exit is
link-edited to the correct library.
Check the TME 10 OPC message log and look for message EQQJ531 or EQQJ615.
260 TME 10 OPC Messages and Codes