![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/cb/2cb81304-d7a7-44a3-9955-4dc95683fc54/2cb81304-d7a7-44a3-9955-4dc95683fc54-bgf0.png)
EQQN032E EQQN038E
EQQN032E UNABLE TO OPEN OPC/ESA VSAM FILE
FILE
, VSAM RC =
RC
, REASON =
RSN
Explanation: The TME 10 OPC subsystem or a TME 10 OPC batch job could not open a VSAM dataset.
System action: The messages that follow this message in the message log identify the action taken by the
subsystem or the batch job.
Problem determination: Use the VSAM return code and reason code to determine the cause of the error. For more
information, refer to the appropriate documentation for the MVS/DFP product installed on this MVS/ESA system.
System programmer response: Correct the error, and restart the TME 10 OPC subsystem or batch job.
EQQN033E OPC/ESA VSAM FILE
FILE
IS INVALIDLY DEFINED
Explanation: After opening a VSAM dataset (
FILE
), the VSAM I/O subtask determined that the dataset’s attributes
did not agree with the I/O subtask’s expectations for this ddname. For example, an incorrect size of the VSAM key
could cause this message.
System action: The VSAM file is not opened.
Problem determination: Check that the file is correctly specified in the TME 10 OPC started task procedure. Use
the IDCAMS LISTCAT function to determine the attributes of the file. Check that the relative key position is zero and
that the key size is the same as that defined in
TME 10 OPC Installation Guide
.
System programmer response: Correct the errors, then restart TME 10 OPC.
EQQN034E DAILY PLAN ENDS AFTER FAILURE TO BUILD VSAM LSR POOL, MACRO BLDVRP FAILED WITH
RC=
RCODE
FOR DDNAME=
DDNAME
Explanation: When building a VSAM LSR pool for the file
DDNAME
, the return code
RCODE
from BLDVRP macro
indicated that the pool had not been built.
System action: The Daily Plan job is ended without creating a New Current Plan.
Problem determination: For return code = 0008 the request could not complete due to lack of Virtual Storage. The
Daily Plan JOB allocates 100 times 32K VSAM LSR buffers, for the New current plan VSAM file, above 16 M. For
other return codes this is probably a system error.
System programmer response: For return code 0008 make sure that enough virtual storage is available. Review
the REGION parameter in conjunction with the limits in IEALIMIT/IEFUSI exit. Rerun the daily planning job.
For other return codes save the Message log containing the error and contact your IBM representative.
EQQN035I REFRESH REQUEST ISSUED BY
tsouser
Explanation: The TSO user
tsouser
issued an LTP refresh request.
System action: TME 10 OPC processing continues.
System programmer response: None.
EQQN038E OPC/ESA DID NOT GET ENOUGH STORAGE TO BUILD THE
TABLE
TABLE
Explanation: TME 10 OPC tried to allocate storage to build the specified table but was not able to obtain sufficient
storage.
System action: TME 10 OPC initialization terminates.
System programmer response: Check the region size defined in the TME 10 OPC JCL procedure. Increase the
region size and restart TME 10 OPC.
220 TME 10 OPC Messages and Codes