EQQW532E THE WSA TASK IS TERMINATING DUE TO A SEVERE ERROR. REFER TO THE SYSMDUMP DATA
SET FOR MORE INFORMATION
Explanation: The Work Station Analyzer subtask has encountered a second severe error.
System action: The Work Station Analyzer subtask terminates and a dump of the TME 10 OPC subsystem address
space is generated.
User response: Refer to the SYSMDUMP dataset to determine the cause of the error. If the problem is caused by
either of the exits taken by the Work Station Analyzer, that is by EQQUX001 or by EQQUX002, then the exit must be
updated. After correcting all errors, restart the TME 10 OPC subsystem.
EQQW533E THE WSA TASK WILL ATTEMPT TO RECOVER FROM A SEVERE ERROR. REFER TO THE
SYSMDUMP DATA SET FOR MORE INFORMATION
Explanation: The Work Station Analyzer subtask has encountered a severe error.
System action: The Work Station Analyzer subtask generates a dump of the TME 10 OPC subsystem address
space and attempts to continue normal processing.
User response: Refer to the SYSMDUMP dataset to determine the cause of the error. If the problem is caused by
either of the exits taken by the Work Station Analyzer, that is, by EQQUX001 or by EQQUX002, then the exit must be
updated.
EQQW534E THE WSA TASK HAS DETECTED A LOOP. DOA, CPLREC3P, AND WAP ARE WRITTEN TO MLOG
Explanation: The Work Station Analyzer subtask has tried to start the same operation repeatedly. The associated
DOA, CPLREC3P, and WAP are written to the MLOG. The operation status is set as specified by the
SUBFAILACTION keyword of the JTOPTS statement.
System action: The failing operation is not dispatched, and the Work Station Analyzer subtask continues processing.
Problem determination: Review the MLOG, JT log, and CP to determine the cause of the error.
User response: Contact your system programmer.
System programmer response: This might be a user error or an internal TME 10 OPC error. Keep copies of the
MLOG, JTARC and active JTnn, and CP. If you suspect that this is not a user error, contact your IBM representative.
EQQW539E THE EXECUTE COMMAND FAILED DUE TO INACTIVE WORKSTATION APPL:
APPLID
IA:
IA
OPERATION:
OPNO
Explanation: The Work Station Analyzer subtask has detected that there is no active workstation for the actual
operation.
System action: The Work Station Analyzer subtask will reset the execute indicator. The operation will remain in
status Ready and be scheduled as any normal operation.
User response: If an immediate execution of the operation is desired, either the ordinary workstation or, if the
operation is reroutable, the alternate workstation should be activated. The EXECUTE command can then be reissued.
EQQW750W STC
STCNAME
IS DEFINED AS A SUBSYSTEM THAT IS NOT MANAGED BY
JES
. OPC/ESA
DOES NOT SUPPORT THIS STC
Explanation: The submittor task cannot start this STC, because it is defined as a subsystem not handled by JES.
System action: The corresponding operation is set to ended-in-error with error code OSUB.
System programmer response: Check the active IEFSSN
emin the SYS1.PARMLIB dataset to see if the STC
STCNAME is defined as a subsystem. If it is not defined, contact your IBM representative.