A SERVICE OF

logo

EQQW014E EQQW017E
EQQW014E THE JCC TASK ABENDED WHILE PROCESSING THE FOLLOWING EXIT RECORD:
EXITREC
Explanation: An abend prevented the JCC from processing all SYSOUT datasets for a batch job.
System action: MVS recovery/termination is requested to generate a dump. The JCC attempts to continue normal
operation with the next ending job. The current job is put on the ended-in-error list with an error code of JCCE.
Problem determination: Review the SYSLOG dataset, the TME 10 OPC message log, and the dump dataset to
determine the cause of the error.
Operator response: Note the job name and job number from the exit record. If necessary, set the correct status for
the job manually.
EQQW015E THE JOB COMPLETION CHECKER COULD NOT FIND ANY SYSOUT DATA SETS FOR JOB
JOBNAME
(
JOBNUM
). REPEATED RETRIES HAVE FAILED
Explanation: The JCC has tried to retrieve SYSOUT datasets for a batch job but no datasets have been returned by
the JES.
System action: No more attempts to retrieve SYSOUT datasets are made for the current job. The JCC attempts to
continue normal operation with the next ending job. The current job will be put on the ended-in-error list with an error
code of JCCE.
Problem determination: In a JES3 system, check that the JCC SYSOUT classes are defined as external writer
classes to JES3.
Operator response: Determine the current status of the job. If necessary, set the correct status for the job
manually.
System programmer response: If necessary, correct any incorrectly specified operands in the JCCOPTS statement
and then restart the JCC.
EQQW016E AN UNRECOVERABLE I/O ERROR OCCURRED. SYNAD MESSAGE FOLLOWS:
SYNMSG
Explanation: An I/O error occurred when the event writer was updating the event dataset.
System action: The event writer attempts to continue processing.
Problem determination: The SYNAD routine collects information such as jobname, stepname, unit address, device
type, ddname, operation, error description, and access method. The SYNADAF macro is used to extract this
information. For a detailed description of the layout refer to the appropriate decoumentation for the MVS/DFP product
installed on this MVS/ESA system.
System programmer response: Correct all errors and, if necessary, restart the event writer.
EQQW017E THE EVENT WRITER WAS UNABLE TO OPEN THE EVENT DATA SET
Explanation: The event writer could not open its output dataset, ddname = EQQEVDS.
System action: The event writer issues message EQQW062E and terminates.
Problem determination: Check that ddname EQQEVDS is correctly specified and that the TME 10 OPC started
task is authorized to open the dataset for update.
System programmer response: If necessary restart the event writer.
Chapter 30. EQQWnnn Messages 297