![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/cb/2cb81304-d7a7-44a3-9955-4dc95683fc54/2cb81304-d7a7-44a3-9955-4dc95683fc54-bg93.png)
EQQIC30E EQQIC31E
EQQIC30E INPUT CURRENT PLAN HAS A DATE LATER THAN 1999-12-31. CURRENT PLAN CANNOT BE
CONVERTED
Explanation: One or more of the following dates in current plan header record or common information is later than
1999-12-31, so the current plan cannot be converted for fallback to a release that does not support dates later than
1999-12-31.
In header record:
– Current plan creation date
– Last plan next period end
– Last backup date
– Tail end date
– Report period start date
In workstation record:
– Interval start date
– Interval end date
In AD index record:
– Input arrival date
– Actual completion or deadline date
In remaining slack record:
– Earliest latest start date
In workstation activity record:
– Activity date
In catalog management record:
– Input arrival date
In job log retrieval record:
– Input arrival date
System action: The migration program continues processing by reading the next CONVERT statement from the
input file. Return code for the current CONVERT command will be 8.
System programmer response: A new current plan must be created after fallback.
EQQIC31E INPUT CURRENT PLAN OCCURRENCE
AD
IA
HAS A DATE LATER THAN 1999-12-31. CURRENT
PLAN CANNOT BE CONVERTED
Explanation: One or more of the following dates in a current plan occurrence or operation is later than 1999-12-31,
so the current plan cannot be converted for fallback to a release that does not support dates later than 1999-12-31.
In occurrence record:
– Input arrival date from LTP
– Modified input arrival date or input arrival date from LTP
– Deadline date
– Actual arrival date
– Actual completion date
In operation record:
– Application input arrival date after MCP update
– Planned start date
– Planned end date
– Operation input arrival date
– Operation deadline date
– Latest out date for operation
– Actual start date
– Actual arrival date
– Intermediate start date
– Actual end date
In undecided operation record:
– Input arrival date
System action: The migration program continues processing by reading the next CONVERT statement from the
input file. Return code for the current CONVERT command will be 8.
System programmer response: A new current plan must be created after fallback.
Chapter 12. EQQICnn Messages 127