EQQE013E EQQE018I
EQQE013E ETT FAILED TO ADD
ADID
FOR TRIGGERING EVENT
TRIG
ERROR DETECTED BY MODIFY
CURRENT PLAN INTERFACE
Explanation: TME 10 OPC was unable to add the application because the modify current plan interface detected an
error.
System action: The associated application was not added by ETT, but ETT processing continues normally.
Problem determination: Check the TME 10 OPC message log data for EQQM
xxx
messages (that is, the MCP
messages) preceding this message. These messages give the exact reason why the application could not be added.
User response: Contact your system programmer.
System programmer response: Save the message log dataset containing these error messages, then contact your
IBM representative.
EQQE014E ETT FAILED TO ADD
ADID
FOR TRIGGERING EVENT
TRIG
AD DATABASE NOT OPEN
Explanation: ETT was triggered by an event but could not add the associated application since the AD database
was not open.
System action: The associated application was not added by ETT, but ETT processing continues normally.
Problem determination: This is an TME 10 OPC internal error.
System programmer response: Save the message log dataset containing these error messages, then contact your
IBM representative.
EQQE015W ETT CANNOT TRACK JOB
JOB
EVEN THOUGH APPLICATION
APPL
HAS BEEN ADDED
Explanation: ETT was unable to track the specified job, even though the specified associated application was
successfully added.
System action: The job that triggered the addition of application
APPL
is not tracked by TME 10 OPC. ETT
processing continues.
Problem determination: The track keyword of the job tracking option statement has most likely been defined so that
no tracking should occur.
User response: Review the tracking options and correct if in error.
EQQE016I ETT HAS SUCCESSFULLY ADDED
ADID
FOR TRIGGERING EVENT
TRIG
Explanation: ETT has detected a triggering event (
TRIG
) and has added the associated application (
ADID
) to the
current plan.
System action: Processing continues.
User response: None.
EQQE017I THE ETT FUNCTION IS ACTIVATED
Explanation: The ETT function has been activated from the dialog or has been started during the controller start up
process because ETT(YES) is specified on the JTOPTS initialization statement.
System action: Processing continues.
User response: None.
EQQE018I THE ETT FUNCTION IS DEACTIVATED
Explanation: The ETT function has been deactivated due to a dialog request or because the Event Manager task
has been requested to terminate.
System action: Processing continues.
User response: None.
Chapter 8. EQQEnnn Messages 85