EQQA248E EQQA254E
EQQA248E THE PREDECESSOR TABLE CONTAINS DUPLICATE PREDECESSORS
Explanation: The list of predecessors cannot contain duplicate predecessors.
System action: The system waits for you to respond.
User response: Use the row command D to delete the duplicate predecessors, or change the duplicates.
EQQA249E THE SPECIAL RESOURCE TABLE CONTAINS DUPLICATE RESOURCES
Explanation: The list of special resources cannot contain duplicate resources.
System action: The system waits for you to respond.
User response: Use the row command D to delete the duplicate resources, or change the duplicates.
EQQA250I AD DOES NOT EXIST IN DATA BASE
Explanation: The specified external predecessor application does not exist in the application description database.
This does not prevent you from saving the application as it is.
System action: The system waits for you to respond.
User response: Enter END to save the external predecessor application, or change the external predecessor
application.
EQQA251E AD DOES NOT EXIST IN DATA BASE, ENTER WS NAME
Explanation: The specified external predecessor application does not exist in the application description database,
so the predecessor workstation name cannot be picked up. Therefore, you must specify the predecessor workstation
name.
System action: The system waits for you to respond.
User response: Enter the workstation name of the external predecessor.
EQQA252I PRED OP DOES NOT EXIST IN PREDECESSOR APPLICATION
Explanation: The specified external predecessor operation does not exist in the external predecessor application.
This does not prevent you from saving the application as it is.
System action: The system waits for you to respond.
User response: Enter END to save the external predecessor operation, or change the external predecessor
operation.
EQQA253E PRED OP DOES NOT EXIST IN PREDECESSOR APPLICATION, ENTER WS NAME
Explanation: The specified external predecessor operation does not exist in the external predecessor application, so
the predecessor workstation name cannot be picked up. Therefore, you must specify the predecessor workstation
name.
System action: The system waits for you to respond.
User response: Enter the predecessor workstation name.
EQQA254E PRINT OPERATION
OP
MAY HAVE ONLY ONE CPU PREDECESSOR
Explanation: The print operation number (
op
) can have only one CPU internal predecessor.
System action: The system waits for you to respond.
User response: Delete all except one of the internal predecessors.
Chapter 3. EQQAnnn Messages 19