American Dryer Corp. AD-200 Clothes Dryer User Manual


 
77
5. "DOOR" LED Indicator -
The indicator should be on all the time (even if the dryer is not returning) unless the main door or lint
drawer is open or there is a problem (open circuit in the main door or lint drawer circuit).
NOTE: If the dryer is started (LED display indicator dots are on) and there are no outputs
(heat or motor output LEDs are off) and the "dOOr" input LED is on, the fault
is in the Phase 5 OPL microprocessor controller itself. If the failure was elsewhere
(i.e., dryer's door switch circuit) the LED display would read "dOOr" if a keyboard
entry was attempted. If the LED display indicators are on the door LED input and
motor or heat output LED's are on and the motor or heat is not active (on), then the
problem is not the door switch circuit or the Phase 5 OPL microprocessor controller
and is elsewhere in the dryer.