American Dryer Corp. AD-200 Clothes Dryer User Manual


 
26
6) Direct Spark Ignition (DSI) 24 VAC Transformer
The DSI transformer is designed to step down the operating voltage of the dryer to 24 VAC to operate
the DSI module. This transformer, like
ALL transformers is two (2) sided;
a) Primary Side...
This is the incoming voltage side - 208 VAC, 230/240 VAC, 380 VAC, 416 VAC, 480 VAC - of the
transformer.
b) Secondary Side...
This is the step down side - 24 VAC - of the transformer.
(If the dryer is above 240 VAC a secondary voltage of 240 VAC will also be present.)
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. ALL voltage connections
should be checked and confirmed according to the wiring diagram provided with
the individual dryer. Any damage done to dryer components due to improper
voltage connections will automatically VOID THE WARRANTY.
IMPORTANT: The ADC Service Department must be contacted prior to any wiring change
or conversion because, depending on the change or conversion required, some
parts may have to be added, deleted, or changed. When contacting the ADC
Service Department, they must be given the correct model and
serial numbers for the dryers.
NOTE: Any wiring changes or conversions should be accomplished by a QUALIFIED
ELECTRICAL TECHNICIAN.