American Dryer Corp. AD-200 Clothes Dryer User Manual


 
11
SECTION V
COMPONENT DESCRIPTION
A. Heat Section
The AD-200 dryer uses three (3) types of heat sources: natural gas, liquid propane (L.P.) gas, and steam.
Natural gas and L.P. gas are not directly replaceable. The gas valves need to be modified to use other than the
type of heat specified on the nameplate.
1. ADG-200 (gas) dryers utilizes a Direct Spark Ignition (DSI) module to monitor that a flame is established.
If for some reason the flame signal is lost, the DSI module will shut off the gas valve and not retry ignition
(no try to restart the flame). A spark of approximately 14,000 volts is used to establish a flame. The
DSI module will turn the gas valve on and ignitor and flame-probe will spark for 8 seconds attempting a
flame. Each time the dryer calls for heat the microprocessor controller (computer) will send a 24 VAC signal
through the exhaust hi-limit, sail switch, and oven hi-limit. At that point, the DSI module will try for
ignition.
DIRECT SPARK IGNITION (DSI) SYSTEM COMPONENTS/FUNCTIONS