American Dryer Corp. AD-200 Clothes Dryer User Manual


 
49
H. Door Systems
The AD-200 utilizes two (2) styles of doors, which are Manual Doors and Pneumatic Automatic Doors.
1. Manual Door Description
The Manual Doors run on a single aluminum track with a wheel assembly mounted above the doors and a
channel with teflon strips mounted on the bottom of the doors ...
a. For dryers manufactured as of November 1, 1995, there are trolley bolts located at the top of the doors to
secure the doors onto the track.
b. For dryers manufactured prior to November 1, 1995, there are two (2) adjustment plates located at the top
of the doors to secure the doors onto the track.
In the center portion on the top of the doors there is a magnet used in conjunction with proximity sensors
which are mounted above the doors.
2. Pneumatic Automatic Description and Operation
a. Description
The Pneumatic Automatic Doors run on a single aluminum track mounted above the doors and a split track
mounted on the bottom of the doors. The doors are held on the track by four (4) stainless steel wheel
assemblies located on the top of the doors. Additionally, in the center portion on the top of the doors there
is a magnet used in conjunction with proximity sensors which are mounted above the doors.
b. Operation
There are two (2) 1" bore x 18-3/8" stroke cable cylinders attached to the top of the doors to pneumatically
open and close the doors. When air is applied into the outside ports of these cable cylinders the doors will
open. If air is applied into the inside ports of these cable cylinders the doors will close. On each of the four
(4) ports is a flow control valve used for adjusting the opening and closing speeds of the doors. These flow
controls only vary the speed in the exhaust direction. Air to the cable cylinders is supplied through a 4-way
valve. When 24 VAC is applied to the valve, the doors open... if no power is applied, the doors close. A
3-way is used to supply air to the 4-way valve.
If the EMERGENCY STOP is engaged, the air is automatically exhausted so that the doors can be opened
manually.
1) In a 2-Door application, there are two (2) additional cable cylinders a 4-way added for the operation of
the rear doors.