F. Air Jet Assembly
1. Air Jet Assembly Description
The AD-200 air jet assembly is located in the left front base of the dryer. The air jet is designed to operate
at the end of each cycle for thirty (30) seconds, to remove lint which may have accumulated on the blower
(impellor) fan blades. This function will be interrupted if the main door or lint drawer is opened before
the air jet cycle is complete.
2. Air Jet Component Replacement
a. 24 VAC 3-Way Pressure Valve Replacement
1) Disconnect compressed air supply from the dryer.
2) Discontinue electric service to the dryer.
3) Remove the 1/4" x 1/8" M.P.T. connection from the 3-way pressure valve body.
4) Remove the two (2) #10-16 x 1/2" Crimptite TEK screws.