American Dryer Corp. AD-200 Clothes Dryer User Manual


 
52
c. Cable Cylinder Replacement or Removal
1) Discontinue electric service to the dryer.
2) Remove the two (2) 1/4-20 x 1/2" bolts from each side of the middle guard.
Remove the middle guard.
3) Disconnect the cables in the top of the electrical panel.
4) Remove the hardware from the top guard.
Remove the top guard.
5) Remove the two (2) 8-32 x 3/4" screws on each door that connect or attach the cable cylinder to the
door.
6) Remove the four (4) 8-32 x 2-1/2" screws that hold each cable cylinder.
7) Remove the flow control valve ...
a) The flow control valve has a quick disconnect on the poly flow tubing side ...
Push the tubing in while holding in then pull the tubing out.
8) To install new cable cylinders or reinstall cable cylinders, reverse above procedure (steps #7
through #1).