American Dryer Corp. AD-200 Clothes Dryer User Manual


 
51
b. Pneumatic Automatic Door Replacement or Removal
1) Discontinue electric service to the dryer.
2) Remove the two (2) 1/4-20 x 1/2" bolts from each side of the middle guard and rear guard.
3) Remove the three (3) 1/4-20 x 3/4" bolts from the bottom guard.
Remove the bottom guard.
4) Remove the two (2) 8-32 x 3/4" screws on each door that connect/attach the cable cylinder to the
door.
5) Remove the two (2) 1/4-20 x 1-1/4" hex head machine screws ...
a) Take notice to the wheel assembly configuration.
6) Lift the door(s) off of the track and remove.
7) To install new pneumatic automatic doors or to reinstall pneumatic automatic doors, reverse above