American Dryer Corp. AD-200 Clothes Dryer User Manual


 
58
SECTION VI
BASIC TROUBLESHOOTING
IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY
and THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE
REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR
CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY
EQUIPMENT PER OSHA (Occupational Safety and Health Administration)
STANDARDS.
The information provided will help isolate the most probable component(s) associated with the difficulty
described. The experienced technician realizes, however, that a loose connection or broken/shorted wire may be
at fault where electrical components are concerned, not necessarily the suspect component itself. Electrical parts
should always be checked for failure before being returned to the factory.
IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the
fuse being replaced. The information provided should not be misconstrued as a
handbook for use by an untrained person in making repairs.
WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BY A
QUALIFIED PROFESSIONAL or SERVICE AGENCY.
WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS
DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.
A. No Display...
1. EMERGENCY STOP button pushed in.
2. Service panel fuses blown or tripped breaker.
3. Blown F1 (fuse 1) or F2 (fuse 2) on right hand control panel.
4. Blown F4 (fuse 4) on right hand control panel.
5. Failed microprocessor controller (computer).
6. Optional sprinkler circuit emergency relay not engaged ...
a. Service panel fuse blown or tripped breaker.
b. Sprinkler circuit is activated.
NOTE: SPRINKLER MUST HAVE POWER FOR THE DRYER TO OPERATE.