NOTE: To reset the DSI module if it is in the "LOCK-OUT" mode, open and close the main
door, then restart the dryer.
(a) To check or set the 1/8" GAP, use a DSI Gap Feeler Gauge or similar device to determine
GAP size. DO NOT USE FEELER TO SET THE GAP, use it only to determine the size
of the gap. If an adjustment is necessary, bend the ground rod to achieve the correct GAP,
then recheck the 1/8" GAP with a feeler gauge.
(b) The ALIGNMENT of the ignitor and flame-probe assembly in relation to the GAP on the
ignitor electrode and ground rod must be maintained in as vertical (straight line) a position as
possible (refer to the illustration below) otherwise the DSI module will indicate a system
malfunction and go into the "LOCK-OUT" mode (the L.E.D. [light emitting diode] indicator
will LIGHT "RED" CONTINUOUSLY).
(c) The POSITIONING of the ignitor and flame-probe assembly is extremely important because
it provides the necessary feedback information to the DSI module. The flame probe electrode
must be POSITIONED 1/4" minimum into the flame path (refer to the illustration below)
and must be POSITIONED one (1) inch maximum from the burner tube (refer to the
illustration below) otherwise the DSI module will indicate a system malfunction and go into
the "LOCK-OUT" mode (the L.E.D. indicator will LIGHT "RED" CONTINUOUSLY).