Alliance Laundry Systems Stacked Clothes Dryer Washer/Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Installation
510975
32
Figure 20
D233I
1 New Stainless Steel Flexible Connector
Use only if allowed by local codes
(Use Design A.G.A. Certified Connector)
4 Black Iron Pipe
Shorter than 20 (6.1 m) Use 3/8" pipe
Longer than 20 (6.1 m) Use 1/2" pipe
2 1/8" N.P.T. Pipe Plug
(For checking inlet gas pressure)
5 3/8" N.P.T. Gas Connection
3 Equipment Shut-Off Valve Installed within 6
(1.8 m) of dryer
D233I
1
2
3
4
5