Alliance Laundry Systems Stacked Clothes Dryer Washer/Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Installation
510975
26
Four-Wire Power Cord
IMPORTANT: Use only a U.L. listed No. 10 AWG
(copper wire only) four conductor power supply
cord kit rated 240 Volts (minimum) 30 Amperes
and labeled as suitable for use in a clothes dryer
unit.
NOTE: The power cord is not supplied with the
dryer unit when the dryer unit is shipped from the
factory; therefore, disregard steps 2 and 3 below
when connecting a four-wire power cord to a new
dryer unit.
If the dryer unit has a three-wire cord attached,
then complete steps 1 through 12.
Remove three-wire power cord
1. Remove the screw holding the access plate to the
rear of the dryer unit cabinet.
2. Remove the three screws holding the three wires
to the terminal block terminals. Save these
screws.
3. Loosen the strain relief screw and pull the cord or
wires out through the rear of the dryer unit.
4. Remove the terminal bracket ground screw
holding the ground wire to the terminal block
mounting bracket. Save the screw.
NOTE: ON NEW DRYER UNITS, this is the
ground wire that goes from the neutral (center)
terminal on the terminal block to the mounting
bracket.
Install four-wire power cord
5. Route the end of the four-wire power cord
through the strain relief. DO NOT tighten the
strain relief screws at this time.
6. Insert the end of power cord and strain relief
through the hole in the rear of the dryer unit
cabinet. Install the strain relief nut from the
inside of the cabinet and tighten firmly.
7. Attach the green ground wire (from the four-wire
power cord) to the terminal block mounting
bracket using the hex head screw removed in
step 4. Tighten the screw firmly.
8. Using the three wire-binding (10-32 x 3/8")
screws from the accessories bag located inside
the cylinder (unless the screws were previously
removed in step 2), attach the power cord wires
to the terminal block terminals as follows:
a. Red to Red
b. Black to Black
c. White to White (refer to NOTE below)
NOTE: When installing the white wire, loop the
free eyelet end of the ground wire (from step 4) and
place it together with the white wire and attach
both wires to the neutral (center) terminal on the
terminal block. Refer to Figure 17.
IMPORTANT: Failure to tighten the nuts firmly on
the terminal block may result in power cord wire
failure.
9. Tighten the two strain relief screws to secure the
power cord.
10. Recheck all screws to be sure they are tight.
To reduce the risk of electrical shock,
disconnect the electrical power to the
dryer unit before proceeding.
W151
WARNING