Step 4: (Electric Dryer Only) Connect
Electrical Plug
For further assistance, refer to section on Electrical
Requirements.
IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three conductor power supply
cord kit rated 240 Volts (minimum), 30 Amperes
and labeled as suitable for use in a clothes dryer.
NOTE: For more detailed information on
connecting three-wire or four-wire plugs, refer to
section on Electrical Connection.
Four-wire cord is required for mobile homes or
where codes do not permit grounding through
neutral.