Page 96 of 906 Acceptance tests
553-3001-211 Standard 3.00 August 2005
3 End the session in LD 30:
****
End of Procedure
Trunk cards
Use the following procedures to test a trunk card.
Procedure 8
Testing a trunk card using a maintenance telephone
1 Access the system from a maintenance telephone.
See “Communicating with the Meridian 1” in the Software Input/Output:
Administration (553-3001-311) for details on accessing the system from a
maintenance telephone.
2 Test the trunk unit:
LD 36
TRK l s c u loop, shelf, card, and unit numbers
3 If the maintenance telephone is hooked up to a monitor and the system
response is other than OK, see the Software Input/Output: Administration
(553-3001-311) to analyze the messages.
End of Procedure
Procedure 9
Testing a trunk card using a system terminal
1 Log into the system:
LOGI (password)
2 Enter:
LD 36
3 To test a trunk from a remote test center, seize a central office (CO)
monitor trunk:
CALL
or
CALL l s c u
Seize the automatic number identification (ANI) trunk:
TRK l s c u loop, shelf, card, and unit numbers