A SERVICE OF

logo

ActiveSync / Get Connected Process 129
E-EQ-MX7RG-B MX7 Reference Guide
Connect -- Initial Install Process
Connect the correct** cable to the PC (the host) and the MX7 (the client). Tap the | Programs
| Communication | Connect icon on the MX7.
The MX7 connection is made using
| Programs | Communication | ActiveSync.
** Cables for initial ActiveSync Configuration:
USB Client to PC/Laptop MX7A052MULTICBLUSB
Serial Client to PC/Laptop MX7A055MULTICBLDA9F
When the desktop/laptop computer and the MX7 successfully connect, the initial ActiveSync
process is complete.
Change Connection Parameters
Tap the | Settings | Control Panel | PC Connection. Tap the Change Connection button.
From the popup list, choose
Option Description
USB (Default) This will set up the MX7 to use the USB port direct.
COM1 @ 57600 This will set up the MX7 to use COM 1 direct at 57600 baud
Tap OK and ensure the check box for “Enable direct connections to the desktop computer”
is checked.
Tap OK to return to Settings.
Select Scanner and ensure the integrated scanner is set to a port that is different than the
“Connect” port (COM 1).