16-70 ELECTRICAL SYSTEM
Meter, Gauge, Indicator Unit
Water Temperature Meter Check:
Connect t he 12 V battery and terminals in the same man-
ner as s
pecified in the "Liquid Crystal Display (LCD) Seg-
ments C heck".
Connect the variable rheostat [A] to the terminal [8] as
shown
.
Check that the number of segments matches the resis-
tance value of the variable rheostat.
Resistance Temperature Warning
Value ()
Meter Indicate
[A]
209.8
50°C (122°F)
[B]
69.1 80°C (176°F) [B]
21.2
120°C (248°F) [C] Flash
17 HI [D] Flash
If any display function does not work, replace the meter
unit.