American Dryer Corp. AD-95 Washer/Dryer User Manual


 
23
To Replace HSI Module
1. Discontinue power to the dryer.
2. Remove the wires connected to the terminal strip at the bottom
of the module. (Mark correct location of each wire to aid in
replacement on new module.)
3. Remove the four (4) pal nuts securing the module to the
mounting bracket.
4. Replace module by reversing procedure.
5. Reestablish power to dryer.
C. Thermostats
To Replace Burner Hi-Limit Thermostat (Gas
Models Only)
1. This thermostat is an important safety device as an added
protection against failure of the air flow (sail switch) to open in
the event of motor failure or reduced airflow conditions.
IMPORTANT: Under no circumstances should heat circuit
safety devices ever be disabled.
NOTE: Models manufactured as of 1998 are equipped with a
manual reset hi-limit thermostat.
1. Discontinue power to dryer.
2. Disconnect wires from hi-limit thermostat.
3. Remove the two (2) screws, washers and nuts securing
thermostat to the bracket. Remove thermostat.
4. Reversing procedure for installing new thermostat.
5. Reestablish power to dryer.
To Replace Lint Compartment Hi-Heat Protector (225º) Thermostat
This thermostat is part of the "sensor bracket assembly" and is secured to the underside of the basket wrapper in
the lint compartment. As a safety device, this thermostat will open (shut off) the heating unit circuit if an
excessive temperature occurs. The dryer motor will remain on, even if the thermostat is open.
1. Disconnect power to dryer.
2. Open lint door.
3. Locate sensor bracket assembly and loosen the two (2) Phillips head
screws securing bracket assembly to the tumbler wrapper.
NOTE: Do not remove the screws.