American Dryer Corp. AD-95 Washer/Dryer User Manual


 
19
To Replace Keyboard Label Assembly
1. Discontinue power to dryer.
2. Unplug keyboard ribbon from rear of computer.
3. Slowly peel off and remove keyboard label assembly from control panel.
4. Peel paper backing off new keyboard label assembly.
5. Holding the new keyboard label assembly close to the panel, insert the keyboard ribbon through the
rectangular slot in the control panel. Align label assembly into
position by matching the red viewing window on the label
to the rectangular cutout in the panel and gently press into
place.
6. Connect keyboard ribbon to the computer.
7. Reestablish power to dryer.
To Replace Microprocessor Temperature Sensor
Probe
1. Discontinue power to the dryer.
2. Open lint door.
3. Remove microprocessor sensor bracket assembly from
dryer.
a. Disconnect sensor bracket harness connector.
b. Loosen the two (2) Phillips head screws which
secure bracket assembly to dryer and remove
bracket from dryer.
NOTE: Do not remove screws.
4. Disassemble sensor probe from bracket assembly by removing the top push-on fastener securing the
probe from bracket. Use a small screwdriver to slowly pry the fastener off.
5. Disconnect the two (2) orange wires from the high heat (225º F) thermostat, and remove modular bracket
connector, wires, and probe from bracket assembly.
6. Install new sensor probe assembly (ADC P/N 811710) by reversing procedure.
7. Reestablish power to the dryer.
NOTE: If, when power is reestablished, the computer display reads "TEMP SENSOR FAIL CHECK
TEMP SENSOR FUSE," check for a loose connection in the wiring.