Alliance Laundry Systems H242I Washer/Dryer User Manual


 
504509 25
Gas Dryer
Electrical Requirements
(120 Volt, 60 Hertz, With 3-Prong Grounding Plug)
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
The dryer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a 15 ampere fuse, equivalent fusetron or
circuit breaker.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 120 Volts AC
(alternating current) 15 Amps. See illustration below
for determining correct polarity of the wall receptacle.
NOTE: A qualified electrician should check the
polarity of the wall receptacles. If a voltage reading is
measured other than that illustrated, the qualified
electrician should correct the problem.
DO NOT OPERATE OTHER APPLIANCES ON THE
SAME CIRCUIT WHEN THIS APPLIANCE IS
OPERATING. DO NOT OVERLOAD CIRCUITS!
DO NOT operate both a washer and gas dryer on the
same ciruict. Use separately fused 15 Amp circuits.
. . .
To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of the
National Electrical Code ANSI/NFPA 70 or the
Canadian Electrical Code, CSA C22.1, and
such local regulations as might apply. It is the
customer’s responsibility to have the wiring
and fuses checked by a qualified electrician
to make sure the laundry room has adequate
electrical power to operate the dryer.
W035
WARNING
This dryer is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.
W036
WARNING
To reduce the risk of an electric shock or fire,
DO NOT use an extension cord or an adapter
to connect the dryer to the electrical power
source.
W037
WARNING
D009IE0C
DO NOT
OVERLOAD
CIRCUITS
DO NOT
USE AN
ADAPTER
DO NOT
USE AN
EXTENSION
CORD
D090IE1B
STANDARD
120 VOLT,
60 HERTZ,
3-WIRE EFFECTIVELY
GROUNDED CIRCUIT
NEUTRAL
SIDE
ROUND
GROUNDING
PRONG
GROUND
NEUTRAL
L1
0
V.A.C.
115 ± 12
V.A.C.
115 ± 12
V.A.C.