6-13
NOTE: Possible Cause/Tests must be performed in the sequence shown for
each problem
POSSIBLE CAUSE/TEST
PROBLEM
WILL NOT DRAIN
MACHINE VIBRATES
1. Remove shipping system.
2. Check installation.
3. Check leveling feet.
INCORRECT
WATER
TEMPERATURE
DISPLAY IS
FLASHING
See “Failure/Error Display Codes.”
1. Unplug washer or disconnect power.
2. Check wire harness connections.
3. Check drain pump.
4. Check drain pump motor.
5. Check that the drain hose and drain pump filter are clear of foreign objects.
6. Plug in washer or reconnect power.
7. Verify CCU operation by running a Diagnostic test or any cycle.
1. Check that the inlet hoses are connected properly.
2. Unplug washer or disconnect power.
3. Check the water heater and wire harness connections to it.
4. Check water temperature sensor for an abnormal condition (see “Water
Temperature Sensor”).
5. Plug in washer or reconnect power.
6. Verify CCU operation by running a Diagnostic test or any cycle.