4-10
REMOVING THE INLET VALVES
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the top cover and the console
(see page 4-2 for the procedures).
Inlet Valves
4. Disconnect the two wire connectors from
the inlet valve terminals.
5. From behind the washer, remove the inlet
valve screw, then slide the valves to the
right and unhook them from the panel, and
remove them.
6. Loosen the clamp and disconnect the hose
from the water valves.
Rear Of Washer
Inlet Valve
Screw
Disconnect Hose
Disconnect
2 wire connectors