Alliance Laundry Systems PHM1401C Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Machine Identification
F8138801
58
Unbalance Error
If the control detects an unbalanced load during a
cycle, the control will run the subsequent Spray Rinse
Extract and Extract steps but only at a reduced speed
and will continue the machine cycle. When the
machine cycle is completed, the control will not
display an error but will increment the Unbalance
Errors audit counter. The control saves the error type,
cycle, segment and step in which it happened and the
date and the time on the Alarms (1 of 4) Menu. The
machine cycle has already ended and the user is only
given the option of unlocking/opening the door and
returning to the Cycle Menu. View “Unbalance” on
the Alarms (3 of 4) Menu for the total error count.
Heat Alarm Error
When the Heat Alarm time is exceeded, the control
will stop the cycle, display the Cycle Stopped Error
Menu and count and record the Total Water Heater
Errors audit counter. The control saves the error type,
cycle, segment and step in which it happened and the
date and the time on the Alarms (1 of 4) Menu. The
audio signal will also be turned on for the error
condition. The Cycle Stopped Error Menu is displayed
alternating with the Run Menu (3 seconds Error Menu/
3 seconds Run Menu) with the Alarm on until the
appropriate user input occurs. The user can continue or
abort the machine cycle. View “Heat” on the Alarms
(3 of 4) Menu for the total error count.
Water Level Sensor Error
If the control senses a High Water Level from the
analog Water Level Sensor during an Extract cycle
step, the control will abort the machine cycle, display
the Cycle Aborted Error Menu, and record and count
the Water Level Sensor Errors audit counter. The
control saves the error type, cycle, segment and step in
which it happened and the date and the time on the
Alarms (1 of 4) Menu. View “Level” on the Alarms (3
of 4) Menu for the total error count. The audio signal
will also be turned on for the error condition. The
Cycle Aborted Error Menu is displayed with the
Alarm on until the appropriate user input occurs. The
machine cycle is aborted and the user is only given the
option of clearing the Cycle Aborted Error Menu and
returning to the Cycle Menu.
PDA Communications Error
These errors may occur during communications.
When an error occurs, the display shows the
Communication Error Menu. The display on the front-
end control will indicate the error by displaying a table
with the Error type. The Error Menu is automatically
cleared from the display after three (3) seconds. When
a PDA error occurs, the audit counter Total Bad PDA
Communications is increased by one and the hour and
date of the event. The error code is saved. This error is
not saved on the Alarms (1 of 4) Menu. View “IR” on
the Alarms (3 of 4) Menu for the total error count.
Water Leak Detection Error
If the control detects a water leak or related problem,
the control will display a Water Leak Detection Error
as described below.
Water Leak Detection During a Machine Cycle
If the Water Leak Detection Error occurs during a
machine cycle, the control will record the error
and display the message “Water Leak Detected”
at the end of the cycle on the Unlock Door Menu.
The control saves the error type as well as the
cycle, segment, step, date and time in which the
error occurred. The error is added to a queue that
holds the last 8 machine errors.
PHM1278R
Figure 72
Water Leak
Detected