Alliance Laundry Systems PHM1401C Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Program Menu
F8138801
36
The and keypads are used to move the
cursor to the different parameters and Internal
Supplies 1 through 5. The and keypads
are used to move the cursor to the External Supplies 1
through 8. Once a supply has been chosen, it is
selected by pressing the keypad. The supply is
activated if it is highlighted. The time can be edited for
each supply step by moving the highlighter box to
time. Press . Blinking underline indicates the
number is ready to be changed.
Pressing the keypad will jump to the Save
Changes Menu.
Agitate Step Menu
The purpose of the Agitate Step Menu is to program
the parameters used while the machine is performing
the Agitate Step. The Agitate cycle step can be turned
on or off. The type of agitation is the first available
parameter. The agitation type parameter menu has
seven (7) choices with 18F/3P/18R (18 seconds
forward, 3 seconds pause, and 18 seconds reverse)
being the default.
The recirculation parameter controls the operation of
the recirculation pump during machine operation. The
user can either turn it on or off. If the water
recirculation option is not enabled in Global Setup
parameter, then this parameter will not display. The
Wash speed can be programmed to either Normal
Wash speed or Reduced Wash speed.
The Agitate step can be programmed to a time from
one (1) minute to 30 minutes.
NOTE: If the Agitate type is programmed to a
value of “No Rotation”, the cycle step time can be
programmed to a value from one (1) minute to 24
hours.
Pressing the keypad will jump to the Save
Changes Menu.
Cool Down Step Menu
The Cool Down Step Menu gives the user the option to
set the Cool Down Option after the Agitation Step.
The Cool Down cycle step can be turned on or off. If
turned off, the control will advance to the next cycle
step (Drain).
The temperature setting allows the user to set the Cool
Down temperature of the water after the Agitation
Step has ended. The temperature will default to cool
down temperature set in Global Setup. To change cool
down temperature, press the and keypads.
Press the keypad to jump to the Save Changes
Menu.
PHM1029R
Figure 32
Modify Cycle
Cycle01: Towels White Bleach
Segment01: Prewash
Agitate:
Type
m m : s s
TimeSpeedRecirc
Reduced
No Rotation
Drain Only
3F/27P/3R
10F/20P/10R
18F/3P/18R
Continuous
NormalOn
Off
4F/56P/4R
PHM1030R
Figure 33
Modify Cycle
Cycle01: Towels White Bleach
Segment01: Prewash
Cooldown:
Temp
GLOBAL