Alliance Laundry Systems PHM1401C Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Machine Identification
57
F8138801
Drive Fault Error
If the control detects the VFD Fault Switch input as
open, the control will log a Drive Fault error and
increment the Drive Fault Errors audit counter. The
control saves the error type, cycle, segment and step in
which it happened and the date and the time on the
Alarms (1 of 4) Menu. View “Drive Fault” on the
Alarms (2 of 4) Menu for the total error count.
Fill Alarm Error
When the Fill Alarm time is exceeded, the control will
stop the cycle and display the Cycle Stopped Error
Menu and count and store the Total Fill Errors audit
counter. The control saves the error type, cycle,
segment and step in which it happened, the date and
the time on the Alarms (1 of 4) Menu. View “Fill” on
the Alarms (2 of 4) Menu for the total error count. The
audio signal will also be turned on for the error
condition. The Cycle Stopped Error Menu is displayed
alternating with the Run Menu (3 seconds Error Menu/
3 seconds Run Menu) with the Alarm on until the
appropriate user input occurs. The user is given the
option of continuing or stopping the machine cycle.
Frame Balance Switch Error
If the control detects a Frame Balance Switch error
during a cycle, the control will abort the machine
cycle, display the Cycle Aborted Error Menu and
count and record the Frame Balance Switch Errors
audit counter. The control saves the error type, cycle,
segment and step in which it happened and the date
and the time on the Alarms (1 of 4) Menu. View
“Frame Balance” on the Alarms (2 of 4) Menu for the
total error count. The audio signal will also be turned
on for the error condition. The Cycle Aborted Error
Menu is displayed with the Alarm on until the
appropriate user input occurs. The machine cycle is
aborted and the user is only given the option of
powering down the machine to service the Frame
Balance Switch error condition.
Open Temperature Sensor Error
If the control senses a temperature less than 5 F in a
machine equipped with a temperature sensor, the
control will abort the machine cycle, display the Cycle
Aborted Error Menu and record and count the Open
Thermistor Errors audit counter. The control saves the
error type, cycle, segment and step in which it
happened and the date and the time on the Alarms (1
of 4) Menu. View “Open” on the Alarms (2 of 4)
Menu for the total error count. The audio signal will
also be turned on for the error condition. The Cycle
Aborted Error Menu is displayed with the Alarm on
until the appropriate user input occurs. The machine
cycle is aborted and the user is only given the option
of clearing the Cycle Aborted Error Menu and
returning to the Cycle Menu.
Rotation Sensor Error
If the control senses an invalid signal from the
Rotation Sensor, the control will continue normal
machine operation as if it had no Rotation Sensor (load
Coast Times), and count and record the Rotation
Sensor Errors audit counter. The control saves the
error type, cycle, segment and step in which it
happened and the date and the time on the Alarms (1
of 4) Menu. View “Rotation” on the Alarms (3 of 4)
Menu for the total error count. The machine cycle will
continue with coast times loaded where rotation
detection is required. It will operate this way until any
loaded coast time has been allowed to expire and the
machine power has been reset. When power is reset,
the machine will acknowledge that it has a rotation
sensor equipped and return to normal operation.
Shorted Temperature Sensor Error
If the control senses a temperature greater than 220 F
in a machine equipped with a temperature sensor, the
control will abort the machine cycle, display the Cycle
Aborted Error Menu and increment the Shorted
Thermistor Errors audit counter. The control saves the
error type, cycle, segment and step in which it
happened and the date and the time on the Alarms (1
of 4) Menu. View “Short” on the Alarms (3 of 4)
Menu for the total error count. The audio signal will
also be turned on for the error condition. The Cycle
Aborted Error Menu is displayed with the Alarm on
until the appropriate user input occurs. The machine
cycle is aborted and the user is only given the option
of clearing the Cycle Aborted Error Menu and
returning to the Cycle Menu.
SPI Error
If the control is unable to communicate with the
Output Board the control will abort the machine cycle,
display the Cycle Aborted Error Menu and increment
the SPI Errors audit counter. The control saves the
error type, cycle, segment and step in which it
happened and the date and the time on the Alarms (1
of 4) Menu. View “SPI” on the Alarms (3 of 4) Menu
for the total error count. The audio signal will also be
turned on for the error condition. The Cycle Aborted
Error Menu is displayed with the Alarm on until the
appropriate user input occurs. The machine cycle is
aborted and the user is only given the option of
clearing the Cycle Aborted Error Menu and returning
to the Cycle Menu.