Alliance Laundry Systems PHM1401C Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Program Menu
F8138801
34
To set parameters in the step menus, move highlight
box to desired step parameter and press ,
the and keypads to change values. In
menus that do not have many values or items to
choose from the vertical arrow keypads will toggle.
NOTE: To change a value, press the or
keypad every time a different item is to be selected.
In menus that have many values or items, the user will
be able to either toggle or slew the or
keypad. Slewing the keypads is when the user holds
down a keypad for a specified amount of time and the
value automatically scrolls through the parameter
being modified. The slewing is based on how much
time the user holds down the keypad. If the keypad is
held down for longer than 2 seconds the value will
begin to scroll.
During the programming of a step, if the keypad
is pressed, the display will jump to the Save Changes
Menu.
Reuse Fill Step Menu
The Reuse Fill Step Menu is used to program the
Reuse Fill step while modifying the Cycle. The Reuse
Fill Step can only be viewed if the Water Reuse
Parameter is turned on (refer to Global Setup Water
Management section), and the fill step for the segment
is turned off otherwise this step is skipped and not
shown. The time for this step is fixed at 5 minutes. The
Fill Alarm is not active for this step. However, the
control will energize cold fill and spray after five
minutes until the water level reaches the programmed
level.
The first programmable parameter of the Reuse Fill
step is the water level. The target water level is either
the programmed global value (High, Medium or Low)
or a specific water level value. Global water level
values are set in the Water Level Menu (refer to Global
Setup, Water Level). For the specific water level value,
1-30 may be selected. The water level can be changed
using the and keypads.
The parameter after water level is valve selectors.
Reuse Fill A, Reuse Fill B, or both may be activated
during the Reuse Fill step. The valve can be selected
and deselected by pressing the keypad. If Reuse
Fill A and Reuse Fill B are deactivated, Aux Fill will
activate by default. If Water Reuse is enabled, the Aux
Fill will be on by default.
Press the keypad to return to Save Changes
Menu.
Fill Step Menu
The Fill Step Menu is used to program the fill step.
The Fill Step contains the parameters the machine will
use when it fills.
Water temperature can be either a global value or a
specific temperature. The global settings are Cold
(COLD), Warm (WARM), or Hot (HOT). The values
for these global settings are set in the Global Setup
Temperature Menu. The specific temperature selection
can either be in Celsius or Fahrenheit depending on
which is chosen in the Global Setup.
The water level can be set to a global value, a specific
level from 1 to 30, or to overflow (OVFL). The global
settings are Low (LOW), Medium (MED), or High
(HIGH).
PHM1025R
Figure 28
Modify Cycle
Cycle01: Towels White Bleach
Segment01: Prewash
Reuse Fill:
Level
High
Valve
Reuse A
Reuse B
Aux Fill
PHM1026R
Figure 29
Modify Cycle
Cycle01: Towels White Bleach
Segment01: Prewash
Fill:
Temp
115 F
Heat
m m : s s
Time
No Heat
To Target
Maintain
Level
Low