Alliance Laundry Systems PHM1401C Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Global Setup
F8138801
44
Alarms Program Menu
The Alarms Program Menu is used to set the fill,
drain, and heat alarm times.
The and keypads are used to move the
highlighted box through the different items in the
Alarm Program Menu. Once the item is highlighted,
the value can be changed by using the
and keypads. Pressing the or
keypad will jump to the Save Changes Menu.
Use or to move highlighted box to “Yes”
or “No”. Press the keypad to return to Global
Setup menu. If no changes were made, press the
or keypad to return to Global Setup Menu.
Rapid Advance Menu
The Rapid Advance Menu has the option of whether
the user will be able to rapid advance through steps
while the machine is operating. Press the
or keypad to change the selection. All
the keypads have the same effect and will toggle the
selection between on or off. Press the or
keypad to jump to the Save Changes Menu. Use
or to move highlighted box to “Yes” or “No”.
Press keypad to return to Global Setup Menu. If
no changes were made, press the or
keypad to return to Global Setup Menu.
If the Rapid Advance Option is enabled (refer to
Global Setup, Rapid Advance section), the user can
advance a running machine cycle with presses of
the keypad. When the keypad is pressed,
the control will immediately show the next cycle step
in the Run Menu but will not change the outputs for a
period of at least five (5) seconds. The user may
advance into any cycle step except the Spray Rinse
Extract and Extract Steps. If the control is executing a
Drain step and the user presses to execute a
Rapid Advance, the control will skip over the Extract
Step. When the cycle is completed, the audit counter,
Total Rapid Advance Cycles is incremented rather
than the Total Machine Cycles audit counter. In
addition this cycle is recorded in the audit list “Last 25
Machine Cycles Completed” and the audit list “Last
10 Machine Cycles Rapid Advanced/Aborted.” Refer
to UniLinc PC and PDA Application User
Instructions for additional information on using a
PDA.
In the Run Menu, the total remaining cycle time is
reduced by the corresponding advance step time if
programmed. If the Rapid Advance Option is disabled
preventing a manual Rapid Advance, the user may still
execute a Rapid Advance using the PDA.
PHM1044R
Figure 50
PHM1045R
Figure 51
Alarms
mm
Fill
5
ss
hmm
00:
Drain
2 00:
Heat
1 30:
Rapid Advance
Enable the Rapid Advance
Feature During Cycle Operation?
NoYe s