M4557 - Model 9210 Nitriding Controller
SSi Manual SERIES 9210-M4557-Nitriding Page 37 of 37
Full Calibration Administrator
Set Menu Security Administrator
Read/Write Raw Data Administrator
Curve Entry Administrator
Alternate PID Setup Administrator
Analog Input Board Setup Administrator
AI Board Calibration Administrator
Program Run Administrator
PLC Calibration Administrator
ADAM Correction Administrator
Aux SP Configuration Administrator
Read/Write Raw Data
This menu is used to view raw data as stored in the 9210.
This is only for use by qualified personnel under direction
of SSI. Contact Super Systems Inc at 800-666-4330
before modifying any of these values. The “Read Offset:”
at the top of the screen will indicate where in the 9210’s
registers the application will begin reading. Press the Edit
button to edit the read offset. Press the Read button to
read the values from the 9210. The application will read
60 registers at a time. Press the Hex button to convert
the values to their hexadecimal counterparts. The Hex
button will now read Dec. Pressing the Dec button will
convert the values to their decimal counterparts. The Dec
button will now read Hex. Pressing the Done button will
close out the menu option. The “Reg:” at the bottom of the screen will indicate where in the 9210’s
registers the application will begin writing. Press the left Edit button to edit the write offset. Press the
right Edit button (next to the Write button) to edit the value to write to the register. Press the Write
button to write the value.
Note: This screen does not continuously update, so the Read button will have
to be pressed to ensure that any changes were made
.
Curve Entry
This menu is not used with the Nitrider Control system and should be ignored.
Alternate PID Setup
This menu is used to allow for up to sixteen different PID
Loops that can be used by the control system. These PID
loops can be used in place of the PID parameters for Loop
1, 2 or 3. To use an alternate PID for a control Loop, it
must be done via the 9210 Recipe. Contact SSI at 800-
666-4330 for assistance with this feature. Use the top
blue up and down arrows to select the separate PID loops.
Use the bottom up and down arrows to select the
parameters for the selected loop. All of the parameters
will display a numeric keypad. The “Proportional Band”
can range from 0 to 999. The “Reset” can range from
0.00 to 10.00. The “Rate” can range from 0.00 to
10.00. The “Integral Preset” can range from –100 to
100. The “High Limit” can range from –100 to 100. The “Low Limit” can range from –100 to 100.