PURGING HOT WATER
Option that permits purging the hot water inlet piping.
Whenever the temperature programmed at the phase is equal to or greater than 50ºC, the hot water inlet
valve of the washing machine and the drain remain open simultaneously during the time specified in this
section.
Configuration only permitted in machines supplied with hot and cold water: value A2 = C in SETUP.
The multi-function and numerical keyboard can be used interchangeably.
This option can increase the water consumption of the washing machine.
Programmable values
0..0.250 seconds
Configuration at works ..... 0 seconds (NO hot water purge)
PURGE DRAIN
Configuration only allowed for machines with drain kit activated (SETUP activation) and programmed purge.
This option allows selecting the drain through which the purging water will be drained
Programmable values
......
Drain 1
Drain 2
Configuration at works ..... Drain 1.
CLEANING DISPENSERS
Option that opens the water inlet valves of the four dosing compartments, before the final drain of the
program, during the time specified in this section.
Its objective is to get rid of product remains that could have been deposited inside.
The multi-function and numerical keyboard can be used interchangeably.
This option can increase the water consumption of the washing machine.
Programmable values
...... 0...30 seconds
Configuration at works ..... 0 seconds (NO dispensers cleaning)
MINIMUM BATH TEMPERATURE
Configuration only permitted in machines supplied with hot and cold water: value A2 = C in SETUP
Option destined to maintain a minimum cold water temperature of 18ºC/64F in all the programs.
In the YES configuration, whenever the temperature programmed is less than 18ºC/64F, the washing
machine mixes hot and cold water until reaching this temperature. The temperature is increased by mixing
water, never by connecting the heating system.
Programmable values
...... YES / NO
Configuration at works ..... NO
NETWORK IDENTIFIER
Option non available.