Alliance Laundry Systems SVN255P Washer User Manual


 
Cod. G522441
© Copyright 2009, Alliance Laundry System LLC – DO NOT COPY OR TRANSMIT Rev. 02/0510
System tools 45
BEEP WHEN PRESSING THE KEY
When pressing a key, the microprocessor emits an acoustic beep. This beep can be annulled.
Programmable values
......
YES / NO
Configuration at works ..... YES
PROGRAMMED DURATION OF THE BUZZER
Modifies the number of acoustic beeps at the end of the phase (section 7.3.14).
The multi-function and numerical keyboard can be used interchangeably.
Programmable values
0 99
Configuration at works ..... 2
PERMISSION OF ACCELERATION
Permits inhibiting the acceleration function described in section 4.4.
Programmable values
...... YES / NO
Configuration at works ..... YES
EXTERNAL BUZZER
Option available only in machines with A6 (I/O2) input and output board installed and activated in the
SETUP menu.
If the external buzzer is activated, the electrical circuit between terminals X4-5 and X4-6 of the A6(I/O2)
board closes when the machine beeps at the end of the cycle. This option permits monitoring the acoustic
beeps to the outside of the machine.
It is a free voltage circuit. Maximum voltage: 240V AC. maximum current: 1A.
Programmable values
...... YES / NO
Configuration at works ..... NO
DOSING TEMPERATURE CONTROL 2 (INTERNAL)
(Option only available in HS-6003, HS-6017; EH030 and EH0409 models.)
The YES temperature control option at the second internal dosing (at works configuration) will supply this
dosing compartment with a hot and cold water mixture depending on the temperature programmed at the
phase .
Programming the NO option at the second internal dosing will supply this dosing department with cold water.
Programmable values
...... YES / NO
Configuration at works ..... YES
LOAD COUNTERS
Actives the individual load counter of each program.
When this option is active, the option to introduce the washer load is displayed at the beginning of the
program.
Programmable values
......
NO; KG (programming of the load in kg); LB (programming of the load in pounds)
Configuration at works ..... NO
PROPORTIONAL WATER LEVEL
This option only appears if the LOAD COUNTER option is activated.
Modify the bath level values in proportion to the selected load.
Programmable values
...... YES / NO
Configuration at works ..... NO
PROPORTIONAL DOSING TIME
This option only appears if the PROPORTIONAL WATER LEVEL option is activated.
Modify the dosing times in proportion to the selected load.
Programmable values
...... YES / NO
Configuration at works ..... NO