Advantech INTRAC-305 Washer User Manual


 
INTRAC-305 OPERATION
© 2011 Advantech Wireless INTRAC-305 MANUAL - Issue 3.2 Page 45
3
CLEAR MODELS
1
2
3
4
5
6
puts the antenna control system into
STANDBY mode and skips to the HOME
menu
skips to the Home (root) menu
skips to the Models menu
skips to the Config menu
skips to the System Setup menu
moves the highlight box to the next field
in the current menu
Current Mode Tracking
Control State Local
Beac Freq 11.452000 GHz
Beac Level -10.05 dB
El Angle 25.37
o
Az Angle 210.50
o
Pol Angle 27.4
o
Standby
Home
Models
Config
System
Setup
Function
Press EN to accept selection
Next
Field
> INTRAC <
IESS-412
NORAD
Path HOME - FUNCTION - MODELS -
MENU KEY 6 (x7) - ENTER
or From Configuration or System Setup
MODELS - MENU KEY 6 (x7) - ENTER
Description With this menu the actual INTRAC orbit model is cleared or
the IESS-412 data and/or the NORAD data is flagged as
being no longer valid.
If, after clearing the INTRAC model, Auto Continue is pressed
the INTRAC enters Learning Mode.
If, after clearing the IESS-412 Model, IESS412 is selected for
“Rapid Model Generate” or for “Program Track” the INTRAC
enters the “Edit IESS-412” menu for the data to be updated.
Similarly if NORAD is selected for “Rapid Model Generate” or
“Program Track” after the NORAD Model has been cleared
the INTRAC enters the “Edit NORAD” menu for the data to be
updated.