Fuse Replacement for the VX5 71
E-EQ-VX5OGWW-F-ARC VX5 User’s Guide
Fuse Replacement for the VX5
The VX5 uses a 100V, 10A time delay (slow blow), high current interrupting rating fuse that is
externally accessible and user replaceable. Should it need replacement, replace with same size,
rating and type of fuse – Littlefuse 0234010 or Optifuse MSC-10A (5x20mm).
T10A, 125V
INPUT:
12-80VDC
6A 72W
AUDIO
ETHERNET /
USB
C
PRODUCT OF U.S.A. U.S. PATENT 5862393
US
U
L
®
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUS T ACCEPT ANY
INTERFERENCE RECEIVED, INCLU DING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
This Class A digital apparatus complies with
Canadian ICE-00 3.
Cet appareil n um de la Classe A est
confirm e l
érique
orme NMB-003 du Canadaà n
CAUTION: For continues protection against risk of fire,
replace only with same type and rating of fuse.
ATTENTION: Pour ne pas compromette la preotection
contre les risques d'incendie, remplacer par un fusible
de mmes types de mmes caractristques nominales.êêé
3
2
1
1. Fuse
2. Twist in this
direction to
remove
3. Twist in this
direction to insert
Figure 71 Fuse Replacement
1.
Turn the VX5 off and disconnect the power cable from the VX5.
Caution:
!
Fuse has voltage on it even when power is off. Always disconnect input
power before changing fuse.
2. While holding the VX5 over a level surface, push the fuse cover in and twist it one
quarter turn counterclockwise. A flat head screwdriver may be used to twist the fuse
cover.
3. Remove the fuse.
4. Discard the fuse and place a new fuse in the holder.
5. Push the fuse in and twist it clockwise one quarter turn.
6. Reconnect the power cable to the VX5.