A SERVICE OF

logo

68 Vehicle 12-80VDC Power Connection
VX5 User’s Guide E-EQ-VX5OGWW-F-ARC
How To: Connect VX5 to a Remotely Mounted UPS Battery Pack
C
A
B
E
D
GND
+
-
Figure 69 Remote Mount UPS Battery Pack Connection
A Vehicle Battery
B Vehicle Power Connection Cable
C UPS Battery Pack
D Extension Cable
E VX5 Computer
1. Connect the power cable to the UPS battery pack by aligning the water-tight connector
pins to the input connector (marked “From Vehicle”); push down on the water-tight
connector and twist it to fasten securely.
2. Connect the output cable (marked “To Computer”) from the UPS battery pack to the
extension cable by aligning the water-tight connector to the input end of the extension
cable; push down on the water-tight connector and twist it to fasten securely.
3. Route the extension cable the shortest way possible. The cable is rated for a maximum
temperature of 105°C (221°F). When routing this cable it should be protected from
physical damage and from surfaces that might exceed this temperature.
Do not expose the cable to chemicals or oil that may cause the wiring insulation to
deteriorate. Always route the cable so that it does not interfere with safe operation and